{"created":"2023-05-15T09:23:43.782861+00:00","id":977,"links":{},"metadata":{"_buckets":{"deposit":"6c808744-4dd5-4bef-9f9f-3deae237a182"},"_deposit":{"created_by":3,"id":"977","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"977"},"status":"published"},"_oai":{"id":"oai:tmdu.repo.nii.ac.jp:00000977","sets":["132:299:300"]},"author_link":["6916","6917","6918","6919"],"control_number":"977","item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1971-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"67","bibliographicPageStart":"51","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"The bulletin of Tokyo Medical and Dental University"}]}]},"item_5_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A reversible hydrocolloid impression material was evaluated by testing the fine line reproducibility, SUI face hardness and dimensional changes of resultant models and also the linear shrinkage of the setting material. It could fully reproduce the 20-micron wide line on the model. The model surface was harder than that from the alginate impressions. Its linear shrinkage when cooled to room temperature was as great as 0.6% and so the impression held in the trays produced models of increased outside dimension and decreased inside dimension. The outside-inside difference was exaggerated by ice water cooling of the impressions.","subitem_description_type":"Abstract"}]},"item_5_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Tokyo Medical and Dental University"}]},"item_5_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.11480/btmd.180104","subitem_relation_type_select":"DOI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright ©1971 Tokyo Medical and Dental University (TMDU)"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2435-0761","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-10-01"}],"displaytype":"detail","filename":"04_Nakazato.pdf","filesize":[{"value":"2.1 MB"}],"format":"application/pdf","license_note":"Copyright ©1971 Tokyo Medical and Dental University (TMDU)","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"04_Nakazato.pdf","url":"https://tmdu.repo.nii.ac.jp/record/977/files/04_Nakazato.pdf"},"version_id":"df7d21fb-d837-4472-a399-0f99d8b2e30a"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ACCURACY OF INDIRECT STONE MODELS MADE FROM REVERSIBLE HYDROCOLLOID IMPRESSIONS","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{}]},"item_type_id":"5","owner":"3","path":["300"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2021-10-01"},"publish_date":"2021-10-01","publish_status":"0","recid":"977","relation_version_is_last":true,"title":["ACCURACY OF INDIRECT STONE MODELS MADE FROM REVERSIBLE HYDROCOLLOID IMPRESSIONS"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-02-09T02:53:04.050041+00:00"}