WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "6c808744-4dd5-4bef-9f9f-3deae237a182"}, "_deposit": {"created_by": 3, "id": "977", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "977"}, "status": "published"}, "_oai": {"id": "oai:tmdu.repo.nii.ac.jp:00000977", "sets": ["300"]}, "author_link": ["6916", "6917", "6918", "6919"], "control_number": "977", "item_5_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1971-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "67", "bibliographicPageStart": "51", "bibliographicVolumeNumber": "18", "bibliographic_titles": [{"bibliographic_title": "The bulletin of Tokyo Medical and Dental University"}]}]}, "item_5_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A reversible hydrocolloid impression material was evaluated by testing the fine line reproducibility, SUI face hardness and dimensional changes of resultant models and also the linear shrinkage of the setting material. It could fully reproduce the 20-micron wide line on the model. The model surface was harder than that from the alginate impressions. Its linear shrinkage when cooled to room temperature was as great as 0.6% and so the impression held in the trays produced models of increased outside dimension and decreased inside dimension. The outside-inside difference was exaggerated by ice water cooling of the impressions.", "subitem_description_type": "Abstract"}]}, "item_5_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Tokyo Medical and Dental University"}]}, "item_5_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.11480/btmd.180104", "subitem_relation_type_select": "DOI"}}]}, "item_5_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright ©1971 Tokyo Medical and Dental University (TMDU)"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2435-0761", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Michihiko, NAKAZATO"}], "nameIdentifiers": [{"nameIdentifier": "6916", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takao, FUSAYAMA"}], "nameIdentifiers": [{"nameIdentifier": "6917", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Michihiko, NAKAZATO", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6918", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takao, FUSAYAMA", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6919", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2021-10-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "04_Nakazato.pdf", "filesize": [{"value": "2.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "Copyright ©1971 Tokyo Medical and Dental University (TMDU)", "licensetype": "license_free", "mimetype": "application/pdf", "size": 2100000.0, "url": {"label": "04_Nakazato.pdf", "url": "https://tmdu.repo.nii.ac.jp/record/977/files/04_Nakazato.pdf"}, "version_id": "df7d21fb-d837-4472-a399-0f99d8b2e30a"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "ACCURACY OF INDIRECT STONE MODELS MADE FROM REVERSIBLE HYDROCOLLOID IMPRESSIONS", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ACCURACY OF INDIRECT STONE MODELS MADE FROM REVERSIBLE HYDROCOLLOID IMPRESSIONS", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "3", "path": ["300"], "permalink_uri": "https://tmdu.repo.nii.ac.jp/records/977", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2021-10-01"}, "publish_date": "2021-10-01", "publish_status": "0", "recid": "977", "relation": {}, "relation_version_is_last": true, "title": ["ACCURACY OF INDIRECT STONE MODELS MADE FROM REVERSIBLE HYDROCOLLOID IMPRESSIONS"], "weko_shared_id": -1}
ACCURACY OF INDIRECT STONE MODELS MADE FROM REVERSIBLE HYDROCOLLOID IMPRESSIONS
https://tmdu.repo.nii.ac.jp/records/977
https://tmdu.repo.nii.ac.jp/records/9775264ba6a-b473-4a18-9d1f-2861c116dded
名前 / ファイル | ライセンス | アクション |
---|---|---|
04_Nakazato.pdf (2.1 MB)
|
Copyright ©1971 Tokyo Medical and Dental University (TMDU)
|
Item type | 学術雑誌論文 / Journal Article_02(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-10-01 | |||||
タイトル | ||||||
言語 | ||||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Michihiko, NAKAZATO
× Michihiko, NAKAZATO× Takao, FUSAYAMA× Michihiko, NAKAZATO× Takao, FUSAYAMA |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A reversible hydrocolloid impression material was evaluated by testing the fine line reproducibility, SUI face hardness and dimensional changes of resultant models and also the linear shrinkage of the setting material. It could fully reproduce the 20-micron wide line on the model. The model surface was harder than that from the alginate impressions. Its linear shrinkage when cooled to room temperature was as great as 0.6% and so the impression held in the trays produced models of increased outside dimension and decreased inside dimension. The outside-inside difference was exaggerated by ice water cooling of the impressions. | |||||
書誌情報 |
The bulletin of Tokyo Medical and Dental University 巻 18, 号 1, p. 51-67, 発行日 1971-03 |
|||||
出版者 | ||||||
出版者 | Tokyo Medical and Dental University | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2435-0761 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.11480/btmd.180104 | |||||
権利 | ||||||
権利情報 | Copyright ©1971 Tokyo Medical and Dental University (TMDU) |