ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. Journal of Medical and Dental Sciences (ISSN 2185-9132)
  2. 68巻

Standardization of examiners using a dental model for pocket probe training: Adequacy of evaluation with a model and standard accuracy rate of skilled examiners

https://tmdu.repo.nii.ac.jp/records/804
https://tmdu.repo.nii.ac.jp/records/804
8e8f52d2-0391-4161-b38e-29e20bf03af2
名前 / ファイル ライセンス アクション
06_Harada.pdf 06_Harada (1.2 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-03-05
タイトル
言語
言語 eng
キーワード
主題 Periodontal pocket
キーワード
主題 Calibration
キーワード
主題 Dental models
キーワード
主題 Periodontics
公開日
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Harada, Yusuke

× Harada, Yusuke

Harada, Yusuke

Search repository
Sunaga, Masayo

× Sunaga, Masayo

Sunaga, Masayo

Search repository
Takeuchi, Yasuo

× Takeuchi, Yasuo

Takeuchi, Yasuo

Search repository
Mizutani, Koji

× Mizutani, Koji

Mizutani, Koji

Search repository
Katagiri, Sayaka

× Katagiri, Sayaka

Katagiri, Sayaka

Search repository
Ikeda, Yuichi

× Ikeda, Yuichi

Ikeda, Yuichi

Search repository
Aoki, Akira

× Aoki, Akira

Aoki, Akira

Search repository
Iwata, Takanori

× Iwata, Takanori

Iwata, Takanori

Search repository
Kinoshita, Atsuhiro

× Kinoshita, Atsuhiro

Kinoshita, Atsuhiro

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objective: To standardize examiners using a dental model, we developed a dental model and conducted a study that found the model was feasible and effective for student practice. However, it remains unclear whether the skill of measuring probing depth (PD) in this model correlates with the skill of measuring PD in patients. Thus, this study was designed to clarify this point and to determine the accuracy rate of a skilled examiner. Material and Methods: Study 1: Fifty-one students measured PD in patients with more than 4 teeth having a pocket equal to or deeper than 4 mm and PD in the model. On the same day, their instructor remeasured PD in these patients. Study 2: Ninety- nine students and 11 Certified Periodontists measured PD in the model. Results: Study 1: The accuracy rate of students measuring patients’ PD equal to or deeper than 4 mm and PD in the model showed a significant positive correlation. Study 2: Based on the receiver operating characteristic curve analysis, the accuracy rate equivalent to the skill level of Certified Periodontists was found to be 84.7%. Conclusion: Standardization of examiners was confirmed with this model. The standard accuracy rate of skilled examiners was found to be 85%.
書誌情報 Journal of Medical and Dental Sciences

巻 68, p. 49-54, 発行日 2021-03
出版者
出版者 Tokyo Medical and Dental University
ISSN
収録物識別子タイプ ISSN
収録物識別子 2185-9132
DOI
識別子タイプ DOI
関連識別子 10.11480/jmds.680006
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 09:40:04.290584
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3